Fairland X20 Swimming Pool Heat Pump Heater

Description

Fairland X20 Swimming Pool Heat Pump Heater

TurboSilence 20 Full-inverter is optimized on Fairland's original Full-inverter tech. Powered by Fairland's self-developed control system, it perfectly matches the inverter-compressor & extreme 3D heat-exchanging tech.

 

COP 20+
COP 20: 1kW Input = 20kW Heat in Return. TurboSilence Full-inverter control system adapts with precise energy consumption solutions, COP up to 20, average COP>15. Even at low temperatures, it can automatically and intelligently control the eco inverter heat pump to produce free heat output according to pool needs.

120% Faster Heating
In addition to the exclusive inverter control system, the upgraded high-performance inverter compressor allows the end user to turbo up the heating capacity to 120% in one touch.

20x Quieter
Mitsubishi twin-rotatory compressor minimizes vibration and achieves low noise operation, the sound pressure is 20 times lower than the traditional On/Off heat pump.

Running Temperature Down to -20℃
Extend swimming seasons to 6 months, 4-season swimming experience

Lightning Heat Exchanger
Fairland has developed a new generation of Lightning heat exchange technology. This innovation redefines titanium heat exchangers by increasing the exchange area by 30% and enhancing efficiency by 30%.

Specifications

MODELX20-11X20-14X20-22X20-32
Advised pool volume (m³)25-4030-5045-7565-105
Operating air temperature (C)-20~43
Performance Condition: Air 26∘C, Water 26∘C, Humidity 80%
Heating capacity (kW) in Turbo mode11.5142232
Heating capacity (kW) in Smart mode9121827.5
COP20.2~7.620.0~7.821~7.420.0~7.3
COP at 50% capacity1515.215.315.1
COP at 20% capacity20.2202120
Performance Condition: Air 15∘C, Water 26∘C, Humidity 70%
Heating capacity (kW) in Turbo mode7.79.214.822.3
Heating capacity (kW) in Smart mode6.47.512.518.5
COP8.7~5.68.1~5.49.0~5.48.3~5.4
COP at 50% capacity7.57.37.67.6
COP at 20% capacity8.78.198.3
Performance Condition: Air 7∘C, Water 26∘C, Humidity 90%
Heating capacity (kW) in Turbo mode6.67.411.817.8
COP7.2~4.97.1~4.67.4~4.57.3~4.7
Sound pressure at 1m dB(A)37.7~44.837.8~45.941.9~49.542.1~50.3
Sound pressure of 50% capacity at 1m dB(A)38.840.343.345.2
Sound pressure at 10m dB(A)17.7~24.817.8~25.921.9~29.522.1~30.3
Heat exchanger
Lightning Heat Exchanger
Casing
Aluminum-alloy Casing
Power supply
230V / 1 Hp / 60Hz
Rated input power at air 15∘C (kW)0.15~1.380.19~1.70.27~2.740.46~4.1
Rated input current at air 15∘C (A)0.65~6.000.83~7.391.17~11.92.01~17.8
Advised water flux (m³/h)2~43~46.5~8.510~12
Water pipe in-out size (mm)50
Net Dimension L×W×H (mm)910×432×660945×432×6601195×432×7601264×536×956
Net weight (kg)636582122